SynchroGrid performed an arc flash analysis on the electrical distribution system for a wind farm operated by Pattern Energy. The study was executed to determine the incident energy levels for 500, 34.5,  0.69 kV equipment, and 240 V AC Panels & 125 DC Panels. Arc-flash hazard analysis was performed using ETAP 18.1.1 software. We made arc flash mitigation recommendations when the incident energy exposures were greater than 40 cal/cm2 as mandated by NFPA 70E.


The Occupational Safety and Health Administration (OSHA) requires employers to protect employees from electrical hazards which includes arc flash. OSHA looks to the prescriptive-based requirements of NFPA 70E to fulfill the performance-based requirements included in its standards. NFPA 70E outlines the safety processes necessary to reduce injuries that can result from being exposed to electrical hazards. 


SynchroGrid can provide you with arc-flash hazard identification and mitigation such that the facility complies with NFPA 70E.

Similar projects

CTT: 345kV Railhead Reactor Addition

SynchroGrid provided relay settings and GOOSE messaging review along with quality control for Cross Texas Transmission's Railhead reactor additions.

CTT: 345kV Gray-Allen Creek Line Addition

SynchroGrid provided relay settings and GOOSE messaging review along with quality control for Cross Texas Transmission's Gray to Allen Creek line additions.

CTT: 345kV Gray Shunt Reactor Upgrade

SynchroGrid provided relay settings and GOOSE messaging review along with quality control for Cross Texas Transmission's Gray shunt reactor upgrades.

Cross Texas Transmission: Voltage Transformer Fault Analysis

SynchroGrid provided an analysis of the operation of a 345kV bus trip. 

Relay Settings for Transformer Feeder and Distribution Feeder

SynchroGrid provided relay settings services for the entire 138 : 12.47kV Substation. 

 

Relay Settings Development and Coordination Study

SynchroGrid provided relay setting and relay coordination services for a local substation. 

Relay Settings for Retrofit Transformer Panel Upgrades

SynchroGrid provided relay setting development services to upgrade two retrofit transformer panels.

Extensive Relay Setting Development and Coordination Services

SynchroGrid developed extensive relay settings as well as relay coordination for a local substation. 

Relay Settings and Coordination Services

SynchroGrid developed relay settings for transformer protection, bus protection, and feeder protection at a local substation. Relay coordination was also provided for the transformer and distribution feeder.

CTT: SEL-487E Reactor Relays Replacement

SynchroGrid upgraded SEL 487E-0 Reactor relays with SEL-487E-3 relays.

CTT: T60 Relay Replacement

SynchroGrid replaced GE-T60 reactor relays with SEL-387E relays and upgraded SEL 487E-0 reactor relays with SEL-487E-3 relays.

NRG: ERCOT RARF Submission

SynchroGrid provided a relay settings review for the ERCOT Region. This was for ERCOT RARF 5.4.

Substation Feeder Addition

SynchroGrid provided relay setting and relay coordination services for a local  substation.

Relay Setting Development for Local Substation

SynchroGrid provided relay setting development services for a local substation.

Pattern Energy: South Kent Wind Arc Flash

SynchroGrid performed an arc flash analysis on the electrical distribution system for South Kent Wind Farm - a wind farm operated by Pattern Energy.

Pattern Energy: Panhandle 2 Wind Arc Flash

SynchroGrid performed an arc flash analysis on the electrical distribution system for a wind farm operated by Pattern Energy.

Relay Settings and Relay Coordination for Local Substation

SynchroGrid developed relay settings and provided relay coordination services for a local substation.

Relay Settings for Feeder and Bus Tie Protection

SynchroGrid provided relay settings for a local substation.

BTU: Enterprise Substation Relay Setting Development & Review

SynchroGrid provided quality system protection services in developing settings for a number of local terminals including Enterprise, TAMU, and Dowling terminals.

CTT: Transmission Line Relay Firmware Upgrade

This project consisted of verifying the adequacy and reliability of new features and settings along with existing settings within the firmware upgrade.

Extensive Relay Setting Development for Texas Utility

SynchroGrid provided quality relay setting development services by creating new settings for relays at five substations for a Texas utility.